PAGE 29 of 29 SENTRY TECHNICAL MANUAL VER1.6
Nothing happens when any call button is
pressed
Check power to the Sentry PCB.
Check the CB line to the door panel. Should be
12Vdc.
No call tone to telephone but speech and
lock ok when handset is lifted
Check terminal T on the telephone for continuity
back to the Sentry PCB
Check the call tone fuse on the Sentry PCB. (If it
repeatedly blows then there is a short on the T line to
the telephones)
Hum on the speech lines
Ensure all intercom cables do not run close to higher
voltage cables
Try another amplifier at the door panel.