SENTRY1 TECHNICAL MANUAL VER1.6
APARTMENT STATIONS
500
The model 500 apartment station includes a push to talk button, door release button and
slide mute switch. The Intercom 3 PCB must be used when using this apartment station.
500M
The model 500M apartment station includes a push to talk button, door release button and
push mute switch with LED and door open LED. The Intercom 3 PCB must be used when
using this apartment station.
DIP SWITCH SETTINGS
8 Way dip switch (Switches 1 – 5)
Mute Duration time
Time 1 2 3 4 5
15 Minutes ON OFF OFF OFF OFF
30 Minutes OFF ON OFF OFF OFF
2 Hours OFF OFF ON OFF OFF
4 Hours OFF OFF OFF ON OFF
8 Hours OFF OFF OFF OFF ON
Connections:
Function
4 Select line from call button
2 Switched +12V to activate
6 Talk Button
1 Lock release button
3 Audio
5 Ground
Connections:
Function
4 Select line from call button
2 Switched +12V to activate
6 Talk Button
1 Lock release button
3 Audio
5 Ground
+ 12Vdc to power mute circuit
D Switch 0V to trigger door open LED
PRIVACY LED FIXED OR FLASHING
FIXED
SW4
FLASHING
Commentaires sur ces manuels