PAGE 29 of 60 VX2200 TECHNICAL MANUAL VER1.4
2280 Bus Interface device
Description
The Art.2280 enables the connection of either the Videx Telephone Interface (Art.380) or the Videx
apartment station (Art.500MM) to the VX2200 system.
Using this device (built into a 5 modules DIN box) it is possible to carry out all the functions available on the
VX2200. For example, answer a call from the door panel (and if necessary open the door), call the concierge
(if present on the system) and intercommunicate with another user (via concierge).
The system draws power directly from the “2 wire” Bus (consumption < of 0.8mA) and from either the 380 or
the apartment station power supply (12Vdc). It includes an 8 way Dip-switch for programming the device with
the phone ID address and a trimmer control for the audio volume towards the door panel.
It is possible to connect up to 180 devices on the same “2 wire” Bus, with the possibility to use the same
address for a maximum of 3 devices (for those applications that require more than one unit in the same
apartment).
Use VX2280 version with 900 series and VX2280-1 with 3000 series.
Operation
In Stand-by mode:
The unit is ready to receive a call.
To answer a call:
Art.380Æ Pick the handset up and speak with the visitor or concierge; press the relevant button to open the
door (see 380 manual) and/or replace the handset to end the conversation.
Art.500MMÆ Press the "TALK" button to speak with the visitor or concierge, release the button to listen,
press the "OPEN" button to open the door and then wait for the time-out to end the conversation.
To call the concierge (if present):
Art.380Æ Pick the handset up, press the relevant button to open the door (see 380 manual) and wait for an
answer.
Art.500MMÆPress the "TALK" button, press the "OPEN" button and wait for an answer.
Programming
Remove the "Settings" cover from the device, set the 8 way Dip-switch with the required address. In case of
mismatched audio level (towards the outdoor station), adjust the trimmer next to the Dip-switch.
Technical Specifications:
Addressing range : from 1 to 180
Working voltage : Bus line voltage and 12V
Stand by absorption/maximum on the BUS : <0.8mA and about 10mA
Stand by absorption/maximum on the 12V : Approx. 5mA
Working temperature : -10 +50 °C
Dip-switches and
microphone volume POT
can be found under this
side cover.