PAGE 17 of 68 VX2200 TECHNICAL MANUAL VER1.5
CONTROL EQUIPEMENT
As there are many variations
of control cabinet available
(Audio, video, with isolation,
multiple door etc). The
components that make up a
control cabinet are listed
below:-
13.8Vdc SYSTEM PSU
Battery backup is a standard
feature of these PSU’s. We
recommend a 7Ah sealed lead
acid battery. 1A, 2A, 3A & 4A
PSU’s are normally used on this
system, all of which have a
regulated output voltage of
13.8Vdc. DC out and battery trickle charge are independently fused.
Additionally the 4A PSU includes a fan out PCB which shares the
available 4A’s between 4 independently fused outputs. The
combination of these fuse values can be anything as long as the 4
outputs are fused to no more than 4A. Fuse values are as follows:-
PSU MAINS FUSE DC OUT FUSE BATTERY TRICKLE CHARGE
FUSE
2 Amp T315mA F2.0A T315mA
3 Amp T630mA F3.0A T315mA
4 Amp T3.15A Main fuse F4.0A. Fan out
fuses can be any
combination up to a total of
4A
T1A
20Vdc VIDEO PSU
The Art.893N1 is a 1A pulse, 800mA continuous
20Vdc PSU. It is a switched output supply
requiring either a positive trigger on terminal ‘+C’
or a negative trigger on ‘-C’ to switch the 20Vdc
output on. There are no fuses in this PSU. If there
is a short on the output or an over current situation
then the PSU will shut down until the problem is
resolved.
CONNECTION FUNCTION
-C 0V trigger to activate output
+C +8-30Vdc to activate output
- 0V output connection
+ 20Vdc output connection
+D 20Vdc output via diode